1.
Sensors (Basel) ; 22(20)2022 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-36298239

RESUMO

Cardiovascular diseases (CVDs) are one of the leading members of non-communicable diseases. An early diagnosis is essential for effective treatment, to reduce hospitalization time and health care costs. Nowadays, an exercise stress test on an ergometer is used to identify CVDs. To improve the accuracy of diagnostics, the hemodynamic status and parameters of a person can be investigated. For hemodynamic management, thoracic electrical bioimpedance has recently been used. This technique offers beat-to-beat stroke volume calculation but suffers from an artifact-sensitive signal that makes such measurements difficult during movement. We propose a new method based on a gated recurrent unit (GRU) neural network and the ECG signal to improve the measurement of bioimpedance signals, reduce artifacts and calculate hemodynamic parameters. We conducted a study with 23 subjects. The new approach is compared to ensemble averaging, scaled Fourier linear combiner, adaptive filter, and simple neural networks. The GRU neural network performs better with single artifact events than shallow neural networks (mean error -0.0244, mean square error 0.0181 for normalized stroke volume). The GRU network is superior to other algorithms using time-correlated data for the exercise stress test.


Assuntos
Cardiografia de Impedância , Teste de Esforço , Humanos , Volume Sistólico , Cardiografia de Impedância/métodos , Redes Neurais de Computação , Algoritmos
2.
Biomed Tech (Berl) ; 61(1): 57-68, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26479338

RESUMO

Wearable home-monitoring devices acquiring various biosignals such as the electrocardiogram, photoplethysmogram, electromyogram, respirational activity and movements have become popular in many fields of research, medical diagnostics and commercial applications. Especially ambulatory settings introduce still unsolved challenges to the development of sensor hardware and smart signal processing approaches. This work gives a detailed insight into a novel wireless body sensor network and addresses critical aspects such as signal quality, synchronicity among multiple devices as well as the system's overall capabilities and limitations in cardiovascular monitoring. An early sign of typical cardiovascular diseases is often shown by disturbed autonomic regulations such as orthostatic intolerance. In that context, blood pressure measurements play an important role to observe abnormalities like hypo- or hypertensions. Non-invasive and unobtrusive blood pressure monitoring still poses a significant challenge, promoting alternative approaches including pulse wave velocity considerations. In the scope of this work, the presented hardware is applied to demonstrate the continuous extraction of multi modal parameters like pulse arrival time within a preliminary clinical study. A Schellong test to diagnose orthostatic hypotension which is typically based on blood pressure cuff measurements has been conducted, serving as an application that might significantly benefit from novel multi-modal measurement principles. It is further shown that the system's synchronicity is as precise as 30 µs and that the integrated analog preprocessing circuits and additional accelerometer data provide significant advantages in ambulatory measurement environments.


Assuntos
Determinação da Pressão Arterial/instrumentação , Monitorização Ambulatorial da Pressão Arterial/instrumentação , Redes de Comunicação de Computadores/instrumentação , Diagnóstico por Computador/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Tecnologia sem Fio/instrumentação , Idoso , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Avaliação Geriátrica/métodos , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Integração de Sistemas
3.
Biomed Tech (Berl) ; 58(2): 121-30, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23482307

RESUMO

This article evaluates several adaptive approaches to solve the principal component analysis (PCA) problem applied on single-lead ECGs. Recent studies have shown that the principal components can indicate morphologically or environmentally induced changes in the ECG signal and can be used to extract other vital information such as respiratory activity. Special interest is focused on the convergence behavior of the selected gradient algorithms, which is a major criterion for the usability of the gained results. As the right choice of learning rates is very data dependant and subject to movement artifacts, a new measurement system was designed, which uses acceleration data to improve the performance of the online algorithms. As the results of PCA seem very promising, we propose to apply a single-channel independent component analysis (SCICA) as a second step, which is investigated in this paper as well.


Assuntos
Algoritmos , Inteligência Artificial , Diagnóstico por Computador/métodos , Eletrocardiografia/métodos , Frequência Cardíaca/fisiologia , Análise de Componente Principal/métodos , Processamento de Sinais Assistido por Computador , Eletrocardiografia/instrumentação , Humanos , Sistemas On-Line , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS